what chemicals did you use to treat the boiler wat

职业技能鉴定 已帮助: 时间:2024-06-14 15:58:46

what chemicals did you use to treat the boiler water ?when you test alkalinity and acidity of water in boiler by pH test paper ? the result shows the boiler water is in acidiity . please describe what the possible cause is .
请帮忙给出正确答案和分析,谢谢!

难度:⭐⭐⭐

题库:职业技能鉴定,海船船员,大管轮

标签:正确答案,请帮忙,water

参考解答

用户头像

427***779

2024-06-14 15:58:46

正确答案:I have ever used the following brand chemicals :unitor , drew and so on . We should keep the boiler water’s ph scale between 10.5 and 11.5 . If the water become of acidity ( ph scale is below 10 ) ,it is may be caused by following reasons : The water has not been given enough blow down ,or has not been filled enough alkalinity chemicals

上一篇 The ship security officer shall have knowledge and

下一篇 The operation of _______two alternators requires t